Skip to main content

APPLICATION

Heat Exchangers for Process Heating

Process heating uses a hotter utility or process stream to raise the temperature of a colder fluid without mixing the two. Ohm Engineers manufactures heat exchangers for this duty from the process data, drawing or EPC specification you issue.

Request a Technical QuoteHeat exchanger types →
Shell and tube heat exchangers manufactured for process heating and cooling duties

What this duty is

A heater is a heat exchanger sized so the cold stream leaves at a specified temperature. The hot side is typically steam, thermal oil, or a hotter process fluid. Selection is driven by duty, allowable pressure drop, fouling, and whether the hot side condenses.

Where it is used

  • Reactor feed and jacket-water heaters
  • Storage-tank and pipeline tracing circuits (when a process exchanger is specified)
  • Column feed preheat
  • Utility water and CIP solution heating where a shell-and-tube unit is the specified construction

Typical services

Steam heating of process liquidsHot-oil heatingProcess-to-process heating (interchangers)Water and glycol heating

Engineering selection

  • Condensing steam on the shell side is common because it gives a high coefficient and even temperature — unless the purchaser specification puts steam in the tubes.
  • Control of outlet temperature is a process/instrument issue. The exchanger is sized for the design case; turndown and bypass must be stated if they affect area.
  • Thermal expansion between a hot shell and cooler tubes favours U-tube construction or a fixed tubesheet with a shell expansion joint when ΔT is large.
  • Do not assume a single steam pressure or heat-transfer area. Those follow the enquiry.

Configurations Ohm manufactures for this duty

Shell & TubePrimary configuration for industrial liquid heaters.U-TubeLarge tube-to-shell temperature difference or removable bundle.Double-PipeModest area or high-pressure inner pipe.

Industries that specify this duty

Sectors — not named customers.

ChemicalPharmaceuticalOil & GasFood & Dairy

What to send with the RFQ

  1. Cold-side fluid, flow, inlet and required outlet temperature
  2. Heating medium (steam pressure / hot oil temperatures / process hot stream)
  3. Operating and design pressures, allowable ΔP
  4. Materials and named design code if any

Related engineering guides

FAQ

What heat exchanger types does Ohm use for process heating?
Configuration follows the duty. Typical starting points are Shell & Tube, U-Tube, Double-Pipe. Send process data — we do not pick a catalogue SKU first.
What information do you need to quote this duty?
Cold-side fluid, flow, inlet and required outlet temperature; Heating medium (steam pressure / hot oil temperatures / process hot stream); Operating and design pressures, allowable ΔP; Materials and named design code if any.

Technical RFQ — Process Heating

Upload a datasheet or drawing if you have one. This is an engineering enquiry, not a retail price request.

Tell us what you need. We will reply by email and ask for process data if a quote requires it.

I have process data — open full engineering RFQ →

WHAT HAPPENS NEXT

  1. We receive your enquiry and reply by email.
  2. If a quote needs process data, we ask for the missing fields.
  3. A technical and commercial response follows when the case supports it.

Direct contact

+91 83470 19128/22
info@ohmengineers.co.in
ohmengineers@gmail.com

RFQ checklist →